Appendix C: Wiring Diagrams and Pin Assignments 85
Appendix C: Wiring Diagrams and Pin
Assignments
LTC Connectors
SYNC peripheral LTC In and LTC Out connec-
tors are balanced XLRs with Pin 2 wired “+” or
“hot,” Pin 3 wired “–” or “cold,” and Pin 1 wired
to ground (shield). Depending on whether you
are connecting a balanced or unbalanced signal
to these connectors, different wiring configura-
tions are recommended for optimum signal in-
tegrity, especially for long cable runs.
If you are connecting a balanced signal to the
SYNC peripheral LTC In or LTC Out connectors:
• Pin 1 and ground should be connected at the
input only (not at the output). This will pre-
vent ground loops between the shield and the
Pin 1 conductor.
If you are connecting an unbalanced signal to the
SYNC peripheral LTC In or LTC Out connectors:
• Connect only Pin 2 to the “+” signal;
• Connect Pin 1 to ground at all inputs and out-
puts.
Wiring diagrams for the SYNC peripheral LTC In and
LTC Out connectors (balanced signal)
LTC In
LTC Out
Device
Device
Wiring diagrams for the SYNC peripheral LTC In and
LTC Out connectors (unbalanced signal)
LTC In
LTC Out
Device
Device