S3L System Guide150
Channel Control Dynamics Parameter
Mapping
The following tables show how Dynamics parameters are
mapped to the Channel Control encoders and their corresponding
In and Sel switches.
Comp/Lim Parameter Mapping
Exp/Gate Parameter Mapping
Control Ranges for Built-In Dynamics
Comp/Lim Defaults and Ranges
Exp/Gate Defaults and Ranges
Channel Control Comp/Lim parameter mapping
Channel
Control
Encoder
Encoder
Rotate
Encoder Sel
Switch
Encoder IN
Switch
1 Threshold level n/a Comp/Lim
in/out
2 Ratio n/a n/a
3 Attack n/a n/a
4 Knee n/a n/a
5 Release n/a n/a
6 Gain level n/a n/a
7 Key HF Key Listen Filter in/out
8 Key LF Key In Filter in/out
Channel Control encoder Exp/Gate parameter mapping
Channel
Control
Encoder
Encoder
Rotate
Encoder Sel
Switch
Encoder IN
Switch
1
Threshold level n/a Comp/Lim
in/out
2
Ratio n/a n/a
3
Attack n/a n/a
4
Knee n/a n/a
5
Release n/a n/a
6
Gain level n/a n/a
7
Key HF Key Listen Filter in/out
8
Key LF Key In Filter in/out
Comp/Lim (defaults to Compressor mode)
Parameter Default Minimum Maximum
Threshold 0 dB –40 dB +20 dB
Attack 10 ms 100 us 200 ms
Release 100 ms 10 ms 4 sec
Ratio 2:1 1.25:1 100:1
Knee 0 (hard) 0 100
Makeup Gain 0 dB –40 dB +20 dB
Exp/Gate Defaults (defaults to Gate mode)
Parameter Default Minimum Maximum
Threshold 0 dB –60 dB +20 dB
Attack 1 ms 20 us 500 ms
Release 250 ms 10 ms 4 sec
Ratio
100:1 (Gate
mode)
1.25:1 100:1
Gate Hold 100 ms 10 ms 4 sec
Gate Range –20 dB –80 dB 0 dB